Cargill Fayetteville (2600016)
Last Update: 09/12/06 ----- 03903T29/FRO ----- EPA | DAQ | EPA-TTN
Hazardous Air Pollutants (Title III and MACT)
- Key Emission Sources: Vegetable oil production sources and boilers, including coal-fired boiler.
- Applicable MACT: Vegetable Oil Production; Solvent Extraction (GGGG) ed=04/12/01, cd=04/12/04.
- Applicable MACT: Boiler MACT (DDDDD) compliance by 2007.
- Key Pollutant: Hexane for vegetable oil production.
- Key Pollutants: Mercury, HCl, and total selected metals for coal-fired boiler.
- GGGG Compl. Strategy: Manage solvent use to limit HAP lost per ton of material processed.
- DDDDD Compl. Strategy: TBD.
- Permit Stipulation: Permit includes specific MACT requirements.
- Similar Facilities: Cargill Raleigh (9200208) has MACT avoidance condition.
- NC Toxics: Limits for n-hexane (94% of AAL) and other hexane isomers (1% of AAL).
- Last Action: Facility submitted electronic copy of compliance plan for Subpart GGGG.
- Next Action: For each month, calculate compliance ratio (actual HAP loss/allowed HAP loss). Submit report for 12-month compliance ratio each June (1st was 60 days after initial 12-month period).
Criteria Pollutants and Hazardous Air Pollutants (Title V)
- Facility Emissions: 2004
- Key Emission Sources: Vegetable oil production and boilers, including coal-fired boiler.
- Key Pollutants for Title V: SO2, VOCs, NOx, PM10, CO, Hexane, HCl, and Hg
- Last Action: Semiannual report was received by 07/30/06.
- Next Action for Title V: Next semiannual report due by 01/30/07.
Chemical Accident Prevention and Response (EPA 112(r) Program)
- No listed chemical above the 112(r) threshold.